Hks Evc 2 Boost Controller Manual

Read all instructions before attempting to set. If you do not have an HKS boost gauge or do. Read this entire manual to understand how the EVC IV functions. Oct 02, 2010 HKS EVC 2 electronic valve boost controller - Duration: 2:30. JapanDyno Performance parts from Japan 1,940 views. HKS EVC 2 Manual - Duration: 0:33.

. EVC6-IR's TFT full color monitor size is enlarged to 2.4 inch from 2.2 inch for better visibility. (The case remains in the same size.).

HKS boost setting tool 'EasyWriter' can be easily connected. Basic performance as a boost controller is the same as EVC6-IR. Correction map grid point: 10 x 10. Pressure correction range: -180 - 180. More precise correction is possible for modern smaller sized turbo.

Monitor Navigation System easily leads the user to the correct setting and logging screens. The proven Stepping Motor is utilized as a valve unit. FUNCTION Display Boost Setting Tool 'EasyWriter' This is for boost setting by PC. Use a marketed USB communication cable to connect EVC and PC.

Hks Evc 2 Boost Controller

Download the software from HKS' website. Connection Diagram. Return-to stock Boost pressure setting returns to stock pressure value when the unit is off.

Controller

Speed Single Input Speed signal input enables the boost control with the speed. (500km/h). Scramble The boost pressure can be increased by a designated value above the set value. Map Correction Input of the throttle signal and engine RPM or vehicle speed signals enables the boost control by a 3D map using 2 these signals as axes. 3-mode Boost Setting Boost pressure can be set in 3 different modes to use them for different conditions. Triple Digital Meter 3 digital data readings of surge tank pressure and throttle angle, engine RPM or vehicle speed can be displayed in real time. 3-mode Offset Setting The differences between the boost pressure set value and actual value can be offset in 3 different modes.

This ensures more precise setting. Bar Graph Selection Select the type of a bar graph from the boost pressure, throttle angle, engine RPM and vehicle speed. Warning If the boost exceeds the warning value, an audible beep and visible warning display notify the user. Also, the boost is lowered to the stock value or a preset value to prevents damage to the engine. Bar Graph Peak Hold The bar graph displays the maximum value after it is reached.

It can achieve easy instant recognition. Throttle Signal Input Throttle position sensor signal input enables the boost control with the throttle angle. After Image The maximum positive boost value is displayed for 3 seconds when the boost changes from positive pressure to negative pressure. Engine RPM Signal Input Engine RPM signal input or ignition signal input enables the boost control with the engine RPM. (1 to 8 cylinders/up to 12000rpm).

Data Memory All settings are stored in the internal memory; so settings will not be lost even when the ignition is off or the battery is disconnected. Display Brightness Selection Select the display unit's brightness from 2 levels.

Exhaust Bypass Selection Select appropriate exhaust bypass type from swing valve type or poppet valve type. Data Lock Data can be locked with a password; it prevents data loss or inadvertent data changes. Unit Selection Select the unit from kPa or PSI. Operation Buttons Side Switchable The side of the buttons can be switched by flipping the monitor vertically. EVC6-IR 2.4 LCD Monitor Size The monitor size is enlarged to 2.4inch for better visibility.